Multistranded and Straight Steel Retainers Show Similar Stability in RCT
A recent randomized clinical trial published in Nature evaluated the short-term stability and periodontal effects of two maxillary fixed retainer types combined with night-time vacuum-formed retainers.
The single-center, two-arm parallel randomized clinical trial utilized a 1:1 allocation ratio to compare multistranded versus straight stainless steel fixed retainers. The study involved twenty-four patients who were randomly assigned to receive either a multistranded retainer or a straight stainless steel retainer following orthodontic treatment.
Clinical evaluations for the trial were performed at appliance removal, designated as T1, as well as at 3 months (T2) and 6 months (T3) post-treatment. Researchers assessed several parameters, including Little’s Irregularity Index, Plaque Index, Gingival Index, probing depth, and bleeding on probing.
The data revealed that Little’s Irregularity Index experienced minor increases in both cohorts over the observation period, though these alterations during follow-up lacked statistical significance. Furthermore, no significant between-group difference in alignment changes was detected, with a p-value below 0.001. Regarding periodontal health, no statistically significant between-group differences were observed in the Plaque Index, Gingival Index with a p-value of 0.415, or probing depth at any assessment.
In a similar fashion, neither the buccal nor the palatal surfaces exhibited any statistically significant variance in bleeding on probing between the groups throughout the evaluation intervals. Even though greater numerical values for palatal bleeding were recorded in the straight stainless steel retainer cohort at the 3-month and 6-month marks, these variations were not statistically meaningful.
Overall, during the first 6 months after orthodontic appliance removal, maxillary anterior alignment remained broadly stable in both retainer groups when used alongside nighttime vacuum-formed retention. The short-term findings do not establish the superiority of either retainer type.
Within the limitations of this short-term trial, the data do not establish a general clinical or periodontal advantage for either retainer design. Consequently, retainer selection should instead consider the clinical context, operator experience, maintenance requirements, and patient adherence. The trial is registered in the Brazilian Register of Clinical Trials under the trial registration number RBR-7hwv8gj.