Skip to main content
World Today News
  • Home
  • News
  • World
  • Sport
  • Entertainment
  • Business
  • Health
  • Technology
Menu
  • Home
  • News
  • World
  • Sport
  • Entertainment
  • Business
  • Health
  • Technology

QST Develops MRI Probe to Visualize Liver Enzyme Activity for MASLD Detection

November 20, 2026 Health Desk Health

Researchers at the National Institutes for Quantum Science and Technology (QST) have developed a molecular probe that enables MRI to visualize metabolic enzyme activity in the liver.

The approach, which utilizes carbon-13-labelled mevalonolactone, offers a noninvasive method for detecting the progression of metabolic dysfunction-associated steatotic liver disease (MASLD) and its more severe form, metabolic dysfunction-associated steatohepatitis (MASH).

Key Clinical Takeaways:

  • The new probe uses [1-13C]MVL to visualize the activity of the liver enzyme paraoxonase (PON) in real time.
  • Researchers achieved a 230,000-fold signal enhancement through hyperpolarization, allowing for liver scans within 20 seconds.
  • The technique demonstrates that PON activity declines as fatty liver disease progresses, providing a potential marker for early clinical intervention.

Current diagnostic standards for liver disease often rely on blood tests that struggle to reflect the local biological environment within the liver. Because PON is primarily produced in the liver and takes part in lipid metabolism and oxidative stress protection, its functional status strongly indicates metabolic health.

“We wanted to find a way to see what enzymes are actually doing inside the living body, rather than relying only on blood tests,” Yoichi Takakusagi, Group Leader at QST’s Institute for Quantum Life Science, told healthcare-in-europe.com.

The research team addressed the limitation of conventional imaging by designing a probe based on [1-13C]MVL. When this probe is introduced, the enzyme PON converts it into mevalonic acid (MVA). By measuring the signals of both molecules, clinicians can map the specific biochemical activity occurring inside the liver tissue.

Detecting metabolic products in a living body requires extreme sensitivity due to the low signal intensity of standard MRI. To overcome this, the QST team employed a SpinAligner hyperpolarizer, which boosted the probe’s signal by approximately 230,000 times. This enhancement remained stable long enough for researchers to capture the metabolic conversion in a 20-second scan.

In testing, the team monitored mice fed a specialized diet designed to induce MASLD and MASH. The results indicated a measurable, progressive decline in liver PON activity that tracked with the development of the disease. This sensitivity allows for the detection of physiological changes before they manifest as advanced anatomical damage, such as cirrhosis or liver cancer.

The ability to visualize biochemical pathways rather than just anatomical structures changes how diagnoses could be made. While currently validated in animal models, the researchers suggest that adapting this molecular-probe design to other enzymes could broaden the utility of hyperpolarized MRI. Such advancements may eventually assist clinicians in identifying patients at risk of rapid disease progression and aid in the development of individualized treatment plans.

The National Institutes for Quantum Science and Technology (QST) was established in April 2016 through the merger of the National Institute of Radiological Sciences (NIRS) with selected operations of the Japan Atomic Energy Agency (JAEA). Its origins trace back to the founding of NIRS in 1957. The institute employs between 1,001 and 5,000 staff and operates with a mandate covering quantum life science, radiation emergency medicine, nuclear fusion, and particle therapy.

Disclaimer: The information provided in this article is for educational and scientific communication purposes only and does not constitute medical advice. Always consult with a qualified healthcare provider regarding any medical condition, diagnosis, or treatment plan.

Share this:

  • Share on Facebook (Opens in new window) Facebook
  • Share on X (Opens in new window) X

More on this

  • How Scalp Care and Head Spas Support Facial Rejuvenation
  • Microrobots Reverse Swimming Direction in Non-Newtonian Fluids Like Blood and Mucus, Study Finds
  • Nature Reports Physics-Encoded Transformer Speeds Coal Mine EM Detection 30,080x (newsy-today.com)

Related

Search:

World Today News

World Today News is your trusted source for global journalism — breaking headlines, in-depth analysis, and reporting from around the world.

Quick Links

  • Privacy Policy
  • About Us
  • Accessibility statement
  • California Privacy Notice (CCPA/CPRA)
  • Contact
  • Cookie Policy
  • Disclaimer
  • DMCA Policy
  • Do not sell my info
  • EDITORIAL TEAM
  • Terms & Conditions

Browse by Location

  • GB
  • NZ
  • US

Connect With Us

© 2026 World Today News. All rights reserved. Your trusted global news source directory.
For contact, advertising, copyright, issues email: [email protected]

Privacy Policy Terms of Service