Microrobots Reverse Swimming Direction in Non-Newtonian Fluids Like Blood and Mucus, Study Finds
“In a sense, they start to back up,” said Ben Ratner, describing what happens to tiny swimming robots when the fluid around them changes.
A research team led by Lehigh University has now shown experimentally, for the first time, that magnetically driven microrobots reverse their direction of travel in fluids like blood and mucus.
The finding, reported by ConSalud, comes from a team led by Ebru Demir, assistant professor of mechanical engineering at Lehigh University’s P.C. Rossin College of Engineering and Applied Sciences, working with collaborators On Shun Pak and Roberto Zenit, according to SaluDigital.
The group studies how microscopic swimming robots — devices designed one day to carry drugs directly to diseased tissue, such as chemotherapy to a tumor while sparing healthy cells — move through body fluids.
Until now, the reversal effect had been demonstrated only in numerical simulations by the same research group. The new work confirms it in the laboratory, and it matters because steering these swimmers through the body is the central obstacle to targeted drug delivery, a goal ConSalud notes remains years away from clinical practice.
- Researchers have experimentally confirmed that swimming microrobots reverse direction in non-Newtonian fluids such as blood and mucus.
- The reversal is driven by fluid properties alone, not by the robot’s shape — both a spherical swimmer and a corkscrew-shaped one showed the effect.
- Understanding this behavior is a step toward controlling microrobots for targeted drug delivery, which would spare healthy tissue and reduce side effects.
Blood and mucus viscosity changes under shear stress
The difficulty lies in what physicists call non-Newtonian fluids. Blood and moco change their viscosity under shear stress — the frictional force generated when layers of fluid slide over one another or along a solid surface such as a blood vessel wall. Water-like, or Newtonian, fluids do not behave this way.
“We found that the rheology, or the properties of the fluid, affected the locomotion of the swimmers,” said Balazadeh Koucheh, a second-year doctoral student in Demir’s research group and lead author of the article, in comments reported by ConSalud. “Specifically, we observed that the swimmer reversed its direction of movement as the actuation frequency increased in a non-Newtonian fluid. This phenomenon had already been demonstrated numerically by our research group, but this is the first time it has been demonstrated experimentally.”
Spheres and corkscrews under a magnetic field
The team tested two types of swimming microparticles: a simple sphere and a helix modeled on the corkscrew shape of certain bacteria. Each carried an embedded magnet, allowing the researchers to spin and propel them with an external magnetic field.
The particles were millimeter-scale, but the team simulated the physics of microscopic swimming by increasing the viscosity of the test fluids. When activated magnetically, the swimmers rotated and moved forward. Raising the rotation frequency made them travel faster. Near a wall, the way the swimmers pushed against the surrounding fluid also pushed them sideways, producing a diagonal trajectory.
Then the researchers placed the swimmers in a synthetic non-Newtonian fluid designed to mimic mucus or blood. Under the same magnetic actuation, the swimmers drifted sideways in the opposite direction from the one they took in the Newtonian fluid.
“It is almost as if changing the fluid changed the finish line for each swimmer,” said Ben Ratner, MS’26, co-lead author of the study, according to ConSalud.
Shape does not matter, rheology does
The reversal appeared in both swimmer designs, which narrowed the cause. “Both types of swimmers showed this backward sliding movement,” Balazadeh Koucheh said. “So now we understand that rheology alone, and not shape, is enough to influence this phenomenon. It is a very interesting finding, since our goal is to control these swimmers inside shear-thinning fluids like mucus and blood.”
That distinction carries weight for the field. If a swimmer’s response to a non-Newtonian fluid is independent of its geometry, engineers designing drug-carrying devices can treat the fluid environment as a control variable rather than an unpredictable hazard, and model behavior across different vehicle designs.
Demir framed the result as a shift in how the machines themselves should be conceived. “The same swimmer behaves completely differently depending on the medium it swims in, and that is a great advantage for control,” she told ConSalud. “Before, we thought of the fluid simply as the medium. Now we are beginning to see it as part of the machine.”
The clinical gap targeted drug delivery has not closed
The motivation behind the work is targeted drug delivery: medication directed only to the tissue that needs it, such as chemotherapy concentrated on a tumor while healthy tissue is spared, minimizing side effects. ConSalud reports that this application remains many years from reality, and findings like this one represent the incremental steps that move the concept from theory to practice.
Patients and clinicians watching this field should read the timeline accordingly: no human application exists yet, and the current results come from synthetic fluids in a laboratory, not from blood vessels in a body.
Oncology patients weighing treatment options today still rely on established standards of care, and questions about chemotherapy regimens and side-effect management belong with a board-certified oncologist or the treating medical team, not with experimental technologies at this stage.
The research team has laid out its own next steps. The next phase is to examine the effects of rheology on swimmers designed at true microscale — the swimmers in this study were millimeter-sized — and with different shapes, according to ConSalud.
From laboratory fluids to blood vessels
The gap between a millimeter-scale particle in synthetic mucus and a micrometer-scale robot moving through a living circulatory system remains wide. Vessel walls, pulsatile flow, immune clearance and real blood’s complex composition all add variables the current experiments do not capture, and the team’s own stated plan — testing microscale swimmers of varied shapes — marks only the next laboratory stage, not a clinical one.
What the experiment establishes is a principle: the fluid is not a passive backdrop but an active component of how these machines move. “Before, we thought of the fluid simply as the medium. Now we are beginning to see it as part of the machine,” Demir said.
Lehigh University, a private research institution in Bethlehem, Pennsylvania, was established in 1865 by industrialist Asa Packer with a focus on engineering and technical education. The university became fully coeducational in 1971 and is classified as an R1 doctoral university for very high research activity.
Disclaimer: The information provided in this article is for educational and scientific communication purposes only and does not constitute medical advice. Always consult with a qualified healthcare provider regarding any medical condition, diagnosis, or treatment plan.