MIT and Partners Develop Dry Polymer for Ultrasound Imaging, Lasts Roughly Nine Days
Engineers at the Massachusetts Institute of Technology and partner institutions have developed a solid, stretchy material that transmits ultrasound waves without requiring traditional acoustic gel, potentially enabling long-term continuous imaging.
The Tech TL;DR:
- A new solid elastomer transmits ultrasound waves without liquid or hydrogel layers that dry out.
- Laboratory tests demonstrated continuous, clear imaging on a synthetic model across nine days.
- Human trials tracked blood flow during a 30-minute bike ride and a 10-minute treadmill run.
Ultrasound scans traditionally require technicians to spread a cold, aqueous gel across a patient’s skin to fill microscopic gaps between the imaging probe and tissue. While fluids allow sound waves to travel efficiently with minimal molecular friction, hydrogels used in previous wearable patches typically dry out within a day or two.
Addressing this limitation, researchers from MIT’s Department of Mechanical Engineering and the Singapore-MIT Alliance for Research and Technology Wearable Imaging for Transforming Elderly Care project published findings on November 19, 2026, in the journal Science detailing a dry elastomer interface.
Solid rubbery materials typically dissipate sound waves because their tangled polymer chains generate friction. To circumvent this, the team engineered a molecular “bottlebrush” configuration consisting of a main backbone with smaller side chains sprouting outward like a pipe cleaner.
These flexible extensions move easily at ultrasound frequencies, reducing internal friction without requiring liquid lubricants. Initial samples proved crumbly, but researchers reinforced the structure by chemically fusing it with a second, loosely connected network of bottlebrush molecules.

The resulting elastomer combines tissue-like mechanics with low-loss acoustics. In tests on a synthetic phantom model, the credit card-sized material maintained clear acoustic signaling for roughly nine days without drying out. During a 10-minute treadmill run, a patch adhered to a volunteer’s chest wicked away sweat, avoiding the waterlogged state that typically disrupts conventional silicone rubber interfaces.
In a field demonstration, investigators attached a key fob-sized patch containing a small ultrasound transducer and the dry bottlebrush layer to a volunteer’s neck. Connected to a portable tablet, the device recorded continuous blood flow data throughout a 30-minute bike ride spanning steep inclines from MIT’s campus to Charlestown and back.

“We are really aiming to address a material challenge in ultrasound imaging,” Shu Wang told LavX News.
Founded by William Barton Rogers and chartered in 1861 to accelerate American industrialization through scientific knowledge, the Massachusetts Institute of Technology held its first classes in 1865. The private research university adopted a German polytechnic model emphasizing laboratory instruction in applied science and engineering.
And we think this really works.”